圆筒形预应力结构锚索间距的确定方法

DETERMINATION OF TENDON SPACING FOR PRESTRESSED COLUMN CASING STRUCTURES

  • 摘要: 圆筒形预应力结构的锚索间距s和单束锚索张拉力P如设计不当,往往会导致预应力轴向分布不均匀,预应力施加过程中会出现环向裂缝。对单束锚索作用下结构内力M、Q、w、q的计算方法进行了简单分析,提出了确定锚索间距的弹性力学叠加公式,并根据工程实例对锚索作用的影响范围和内力变化规律进行了对比验证。结果表明,理论分析成果和现场实测结果是比较吻合的,二者相差不超过5%。提出的叠加公式可用于实际工程的计算分析。

     

    Abstract: Excessive axial moment would be induced and circumferential cracks would appear during tensioning of column casing structures if the prestressing force P and tendon's spacing s were not properly designed. Based on elastic mechanics theories, the formulas for calculating axial moment M, shear force Q, radial displacement w and angle deformation θ are discussed in the paper. A set of superposition formulas for determining the prestressed force P and tendon's spacing s are derived and demonstrated with the field test. It is shown that theoretical results given by superposition formulas are in very good agreement with that of field test, the relative error between them being smaller than 5%. The superposition formulas presented in the paper can be used to determine the prestressing force and tendon's spacing with satisfactory accuracy.

     

/