DU Yi-xin, LIU Jing-bo, WANG Li-bin. A BLAST SHOCK ISOLATION SYSTEM WITH MRFD AND THE SEMI-ACTIVE CONTROL[J]. Engineering Mechanics, 2008, 25(1): 167-172.
Citation: DU Yi-xin, LIU Jing-bo, WANG Li-bin. A BLAST SHOCK ISOLATION SYSTEM WITH MRFD AND THE SEMI-ACTIVE CONTROL[J]. Engineering Mechanics, 2008, 25(1): 167-172.

A BLAST SHOCK ISOLATION SYSTEM WITH MRFD AND THE SEMI-ACTIVE CONTROL

More Information
  • Received Date: December 31, 1899
  • Revised Date: December 31, 1899
  • To effectively reduce the damage of personnel and equipment in civil defense engineering subjected to blast shock wave, a shock isolation system with magnetorheological fluid dampers (MRFD) is established. MRFD can provide continuous and regulable coulomb friction, which is much efficient to reduce the accelerate response of the structure. The numerical simulation is completed by using a few semi-active control algorithms based on the instantaneous optimal active control algorithm. The results prove that the right semi-active control algorithms with suitable parameters can efficiently mitigate the structural response of acceleration.
  • Related Articles

    [1]SHI Yun-dong, DU Yang, HAN Qing-hua, WEI Xin, WU Hao, LIU Ming-jie, TANG Zhen-yun. SHAKING TABLE TESTING ON A SCALED SEMI-ACTIVE CONTROLLED THREE-DIMENSIONAL FLOOR ISOLATION SYSTEM[J]. Engineering Mechanics, 2021, 38(7): 99-107, 119. DOI: 10.6052/j.issn.1000-4750.2020.07.0483
    [2]XU Long-he, LI Zhong-xian, QIAN Jia-ru. TIME DELAY AND COMPENSATION FOR SEMI-ACTIVE PREDICTIVE CONTROL SYSTEM[J]. Engineering Mechanics, 2011, 28(9): 79-083.
    [3]XIAO Zhi-rong, SUN Bing-nan. SEMI-ACTIVE NEUROCONTROL ON STAY CABLE WITH MR DAMPER[J]. Engineering Mechanics, 2010, 27(1): 183-187.
    [4]LIN Wei, LI Zhong-xian, NI Yi-qing. TRUST-REGION METHOD BASED INSTANTANEOUS OPTIMAL SEMI-ACTIVE CONTROL FOR MR DAMPERS[J]. Engineering Mechanics, 2009, 26(9): 36-042,.
    [5]QUAN Wei, LI Hong-nan. SEMI-ACTIVE CONTROL OF CURVED BRIDGE UNDER MULTI-COMPONENT AND MULTI-SUPPORT EARTHQUAKE[J]. Engineering Mechanics, 2009, 26(3): 79-085.
    [6]SEMI-ACTIVE CONTROL FOR WIND-INDUCED RESPONSES OF TRANSMISSION TOWER-LINE SYSTEM USING FRICTION DAMPERS[J]. Engineering Mechanics, 2009, 26(1): 221-226,.
    [7]XU Xiao-long, SUN Bing-nan. INTELLIGENT ALGORITHM BASED SEMI-ACTIVE CONTROL OF MR DAMPER OF NONLINEAR SEISMIC RESPONSE FOR HIGH-RISE BUILDINGS[J]. Engineering Mechanics, 2008, 25(1): 209-216.
    [8]ZHAO Da-hai;<I>&#</I>;LI Hong-nan. VIBRATION CONTROL OF NONLINEAR STRUCTURE BY SEMI-ACTIVE FRICTION DAMPER BASED ON T-S FUZZY LOGIC[J]. Engineering Mechanics, 2007, 24(12): 65-071.
    [9]LI Zhong-xian, CHEN Hai-quan, LI Yan-tao. FINITE ELEMENT ANALYSIS AND SEMI-ACTIVE CONTROL OF PARAMETRIC VIBRATIONS OF CABLE-STAYED BRIDGES[J]. Engineering Mechanics, 2004, 21(1): 131-135.
    [10]SHENG Yan, WANG Chao, PAN Ying. A SEMI-ACTIVE CONTROL LAW FOR MAGNETORHEOLOGICAL DAMPER BASED ON THE LINEAR QUADRATIC GAUSSIAN/LOOP TRANSFER RECOVERY METHOD[J]. Engineering Mechanics, 2004, 21(1): 112-117.

Catalog

    Article Metrics

    Article views (1111) PDF downloads (304) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return